Mfg Part Number: 0A836-5041 | Alternate P/N: 0A8365041 | NSN : 5910-00-147-6824 |
NIIN : 001476824 | CAGE Code : 12578 | Manufacturer: Minnesota Mining And Mfg Co |
Item Name : Capacitor Fixed Mica Dielectric | FSC : 5910 Capacitors |
We at Integrated Purchasing are here to help you secure top quality Capacitor Fixed Mica Dielectric parts like 0A836-5041. This particular NSN component is listed alongside the part number 0A836-5041, having been manufactured by Minnesota Mining And Mfg Co. Reach out by filling out an RFQ for a timely quote and please let us know your desired quantity, price, and shipping time frame so we can make the purchasing process as efficient as possible to meet your specific needs. We have experts working around-the-clock and guarantee a response to your completed form within 15 minutes.
In addition to NSN 5910-00-147-6824, we offer a vast inventory of parts at competitive pricing. We understand the importance of fully informed purchasing and therefore list every item with all applicable information. For example, you can find NSN 5910-00-147-6824 and part number 0A836-5041 which are manufactured by Minnesota Mining And Mfg Co under the CAGE Code 12578. Let us provide you with any information you require in a timely and detailed manner. We have experts working around-the-clock to answer any questions in addition to quotes. Do not hesitate to contact us and allow Integrated Purchasing to do the work for your sourcing, logistics, shipments, and quality so that you can focus on building. Call or email us today to get started!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-147-6824 Item Description: Capacitor Fixed Mica Dielectric | 5910 | 001476824 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
0a836-5041 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.710 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.590 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.360 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.313 INCHES MINIMUM AND 0.375 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBQ | CAPACITANCE VALUE PER SECTION | 1000.000 PICOFARADS SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 500.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00 TO 5.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.0008 |
CWSG | III TERMINAL SURFACE TREATMENT | SOLDER |
TEST | TEST DATA DOCUMENT | 12578-0A836 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWIN |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
![]() |